TABLE I. CONTACT ARRANGEMENT SERVICE RATING
MS Service Rating |
Recommended Operating Voltage* At Sea Level | Effective Creepage Distance Nom. | Mechanical Spacing Nom. |
|
DC | AC (RMS) | |||
Inst. | 250 | 200 | 1/16 | – |
A | 700 | 500 | 1/8 | 1/16 |
D | 1250 | 900 | 3/16 | 1/8 |
E | 1750 | 1250 | 1/4 | 3/16 |
B | 2450 | 1750 | 5/16 | 1/4 |
C | 4200 | 3000 | 1 | 5/16 |
ELECTRICAL SERVICE DATA
Test current ratings of contacts and allowable voltage drop under test conditions when assembled as in service are shown below. Maximum total current to be carried per connector is the same as the allowable in wire bundles as specified in MIL-W-5088.
ALTITUDE VOLTAGE DERATING** CHART | ||||||||
MS Service Rating |
Nominal Distance |
Standard Sea Level Conditions |
Pressure Altitude† 50,000 Feet |
Pressure Altitude† 70,000 Feet |
||||
Airspace |
Creepage |
Minimum Flashover Voltage AC (RMS) |
Test Voltage AC (RMS) |
Minimum Flashover Voltage AC (RMS) |
Test Voltage AC (RMS) |
Minimum Flashover Voltage AC (RMS) |
Test Voltage AC (RMS) |
|
Inst. | 1/32 | 1/16 | 1400 | 1000 | 550 | 400 | 325 | 260 |
A | 1/16 | 1/8 | 2800 | 2000 | 800 | 600 | 450 | 360 |
D | 1/8 | 3/16 | 3600 | 2800 | 900 | 675 | 500 | 400 |
E | 3/16 | 1/4 | 4500 | 3500 | 1000 | 750 | 550 | 440 |
B | 1/4 | 5/16 | 5700 | 4500 | 1100 | 825 | 600 | 480 |
C | 5/16 | 1 | 8500 | 7000 | 1300 | 975 | 700 | 560 |
CONTACT RATINGS | ||||
Contact Size |
Wire Size |
Rated Current |
Potential Drop |
Max Current |
16 & 16S | 16 AWG | 13 A | 49 mV | 22A |
12 | 12 AWG | 23 A | 42 mV | 41A |
8 | 8 AWG | 46 A | 26 mV | 73A |
4 | 4 AWG | 80 A | 23 mV | 135A |
0 | 0 AWG | 150 A | 21 mV | 245A |